GenMoist is designed to automatically and simultaneously dry and weight a solid sample for the determination of moisture content. The machine provides a continuous direct readout for both the weight and the percentage moisture loss through the entire cycle. It has a build-in timer.
GenMoist | |
---|---|
Capacity/Resolution | 160 g x 0.001 g |
Timer | 0-99 min with 1 minute Interval |
Dimensions | 194 x 340 x 235 mm |
Weight Approx. | 11.5 kg |
Weight Range | 160 g |
Readability | 0.001 g |
Tare Range | 160 g |
Linearly Deviation | <±0.001 g |
Stabilization Time (typical) | 3 sec |
Ambient Temperature Range | 10 + 40°Ccm |
Calibration Weight | 100 g |
Line Voltage | 115V-60Hz or 230V-50Hz |
Consumption | 14 VA |
Weight | 15 lbs / 7 kg |
Dimensions (WxDxH) mm | 13.5" x 7.7" x 3.8" / 340 x 194 x 95 |
Data Interface | R2 232 |
The primary purpose of the Moisture Determination Balance - GenMoist is to automatically dry and weigh solid samples to accurately determine their moisture content. This device simplifies moisture analysis by combining drying the sample and measuring its weight, ensuring precise, real-time results. The continuous readout feature provides direct measurements of both the weight and the percentage of moisture lost throughout the entire testing cycle.
Additionally, GenMoist includes a built-in timer, allowing users to set and monitor specific drying intervals for different samples. This function helps achieve consistent and repeatable results, which makes GenMoist ideal for laboratories and industries requiring reliable moisture determination. By automating the drying and weighing processes, GenMoist increases moisture content testing accuracy and efficiency.
Click here to learn more about the product or here to receive a personalized quote.
The Moisture Determination Balance - GenMoist is designed to test a large range of solid materials. It effectively analyzes materials that require precise moisture content determination, such as soils, powders, granules, and other solid samples. This adaptability allows it to be used in industries like soil mechanics, agriculture, food processing, and quality control labs, which require accurate moisture analysis.
Whether testing soil samples for environmental assessments or analyzing powdered substances for manufacturing consistency, GenMoist offers reliable performance. Its automated drying and weighing system guarantees that materials with different moisture levels are handled correctly. With continuous readouts of weight and moisture loss, GenMoist provides detailed insights into each type of solid material tested, improving precision in measurement for a variety of applications.
Click here to learn more about the product or here to receive a personalized quote.
To operate the Moisture Determination Balance - GenMoist effectively, please refer to the following steps. Begin by turning on both the balance and the heater. Allow the heater to reach an internal temperature of 50°C before proceeding, as this temperature is optimal for accurate results. A 30-minute warm-up period is recommended to provide stability and reliability.
Next, calibrate the balance using the calibration weight provided in the package. This step is necessary for measurement precision and should follow the enclosed instructions. Take care to avoid placing heavy items on the balance plate, as excessive weight could damage the balance mechanism. Following these steps, users can maintain balance accuracy and extend its operational lifespan.
Click here to learn more about the product or here to receive a personalized quote.
The Moisture Determination Balance - GenMoist has capacity and resolution designed to support precise moisture analysis of many types of solid samples. Its maximum capacity is 160 grams, allowing it to handle a range of sample sizes effectively. The device provides a high resolution of 0.001 grams, which allows for highly accurate measurements.
This combination of capacity and fine resolution increases the balance’s reliability, particularly in fields where precision is a must, such as laboratory testing, soil analysis, and quality control. With this level of accuracy, GenMoist meets professional moisture determination demands, providing consistent and dependable results.
Click here to learn more about the product or here to receive a personalized quote.
The Moisture Determination Balance - GenMoist features an adjustable timer designed to suit a variety of testing durations. Users can set the timer from 0 to 99 minutes, with adjustments available in 1-minute intervals. This range allows flexibility in selecting the precise drying time needed for different types of solid samples.
The timer feature enables users to customize the drying period to match specific sample requirements, enhancing moisture determination reliability. By allowing controlled and consistent drying times, the GenMoist makes certain that each sample undergoes an optimal testing cycle.
Click here to learn more about the product or here to receive a personalized quote.
The Moisture Determination Balance - GenMoist measures approximately 7.6 x 13.4 x 9.3 inches (194 x 340 x 235 mm). Its compact dimensions make it ideal for use in laboratories and workstations, and its space-saving design makes it suitable for most testing environments.
This size supports ease of use and portability, allowing the balance to be conveniently positioned for regular moisture testing tasks. Its balanced proportions guarantee stability during operation, contributing to consistent and reliable measurement results.
Click here to learn more about the product or here to receive a personalized quote.
The approximate weight of the Moisture Determination Balance - GenMoist, including its packaging and any additional components, is 11.5 kg (around 25.4 pounds). This gross weight measurement accounts not only for the balance itself but also for any protective packaging, calibration weights, and accessories included in the box. This detail is valuable for logistics and transport planning, helping users understand the shipping requirements and the total weight to handle.
When setting up the GenMoist, this approximate weight also indicates how much support is needed to safely move and position the unit in a lab or testing area. For facilities that prioritize space management, this weight information helps determine the most suitable setup area.
Click here to learn more about the product or here to receive a personalized quote.
With a weight limit of 160 grams, the Moisture Determination Balance - GenMoist is capable of measuring a variety of sample sizes. This range is ideal for precise moisture determination in small, controlled sample sizes commonly used in laboratory and quality control settings. With a maximum capacity of 160 grams, the balance provides accurate measurements for each sample, ideal for applications where careful weight control and precision are essential.
This weight range supports industries like soil analysis, food quality testing, and material science, where sample sizes typically remain small. By accommodating weights up to 160 grams, the GenMoist offers flexibility and accuracy, resulting in consistent performance within diverse testing conditions without risking overload or compromising measurement accuracy.
Click here to learn more about the product or here to receive a personalized quote.
The readability of the Moisture Determination Balance - GenMoist is 0.001 grams, meaning it can measure weight changes as small as one-thousandth of a gram. This high level of precision is particularly useful for applications requiring detailed moisture content analysis, as it allows users to detect even the slightest changes in sample weight during testing.
With a readability of 0.001 grams, the GenMoist is ideal for fields where accurate and sensitive measurement is crucial, such as laboratory testing, quality control, and soil mechanics. This fine resolution enables precise readings, improving moisture determination reliability and guaranteeing that measurements accurately reflect the sample’s true moisture content. The 0.001-gram readability makes the GenMoist suitable for environments where precise data is necessary for research, analysis, and quality assurance.
Click here to learn more about the product or here to receive a personalized quote.
The tare range of the Moisture Determination Balance - GenMoist is 160 grams, allowing it to zero out any sample container or additional items placed on the balance up to this weight. This capability enables users to focus solely on the weight of the sample itself, improving accuracy in moisture determination by removing the weight of containers or other sample holders from the measurement.
A tare range of 160 grams is beneficial in laboratory and quality control settings where containers or sample holders are necessary for handling materials. By accommodating up to 160 grams in tare weight, the GenMoist provides flexibility in selecting appropriate containers for different sample types without compromising the balance’s precision. This feature makes certain that only the actual sample weight is recorded, contributing to more reliable and precise moisture content analysis.
Click here to learn more about the product or here to receive a personalized quote.
The linear deviation of the Moisture Determination Balance - GenMoist is less than ±0.001 grams. This specification indicates the balance’s high level of accuracy and consistency, assuring that repeated measurements are highly reliable. Linear deviation refers to the maximum expected variation from the true weight over the entire weighing range, meaning that the GenMoist can maintain accuracy even at different points within its capacity.
With a deviation of less than ±0.001 grams, this balance is ideal for precision tasks in fields like laboratory research, quality control, and soil testing, where even minor deviations can impact results. This minimal linear deviation results in consistent and dependable readings, increasing confidence in measurements, particularly in applications requiring stringent accuracy.
Click here to learn more about the product or here to receive a personalized quote.
The typical stabilization time for the Moisture Determination Balance - GenMoist is 3 seconds. This means that once a sample is placed on the balance, it takes approximately three seconds for the reading to stabilize and display an accurate weight measurement. This quick stabilization time enhances efficiency, especially in busy laboratory environments or industrial settings where rapid and frequent measurements are required.
A 3-second stabilization time allows users to achieve reliable results quickly without prolonged waiting, thereby making GenMoist especially suitable for high-throughput testing procedures. This feature not only saves time but also helps maintain workflow consistency so that each sample is measured promptly and accurately. With this fast stabilization, the GenMoist supports both precision and productivity, which is necessary for applications requiring accurate, rapid moisture analysis.
Click here to learn more about the product or here to receive a personalized quote.
The ambient temperature range for the Moisture Determination Balance - GenMoist is 10 to 40°C (50 to 104°F). This range specifies the optimal environmental conditions for the balance to function accurately and reliably. Operating the GenMoist within this temperature range guarantees that the device performs at its best, as extreme temperatures outside this range could impact measurement precision.
This temperature tolerance makes the GenMoist adaptable to standard laboratory and industrial environments, where temperatures are typically maintained within controlled limits. Using this specified range, users can achieve consistent and accurate moisture determinations, as the balance’s sensitive components are safeguarded from potential environmental interference.
Click here to learn more about the product or here to receive a personalized quote.
The calibration weight for the Moisture Determination Balance - GenMoist is 100 grams. This specific weight is used to verify that the balance is correctly calibrated, providing accurate measurements for each use. Regular calibration using this 100-gram weight helps maintain the device's precision, which is necessary for consistent and reliable moisture content determinations.
Calibration is a very important step, especially in settings where precision is vital, such as research labs, quality control, and soil testing. The 100-gram calibration weight included with the GenMoist allows users to easily recalibrate the device whenever necessary, helping to offset any minor shifts in accuracy that may occur over time. By using the correct calibration weight, users can be confident that their balance remains accurate and aligned with industry standards for precision measurements.
Click here to learn more about the product or here to receive a personalized quote.
The line voltage requirement for the Moisture Determination Balance - GenMoist is 115V at 60Hz or 230V at 50Hz. This dual voltage compatibility allows the GenMoist to be used internationally, meeting many different electrical requirements. Users can select the appropriate voltage setting depending on their location, resulting in safe and efficient operation.
This flexibility in voltage options makes the GenMoist convenient for laboratories and facilities around the world, as it easily adapts to the local power supply. Whether in North America, Europe, or other regions with differing voltage standards, the GenMoist remains adaptable and reliable, helping users avoid compatibility issues and maintain accurate moisture measurements.
Click here to learn more about the product or here to receive a personalized quote.
The Moisture Determination Balance - GenMoist consumes 14 VA, indicating the amount of electrical power it requires. This relatively low power consumption makes the GenMoist energy-efficient, which is beneficial for laboratories and facilities focused on minimizing energy usage without compromising performance.
Operating at 14 VA means the GenMoist consumes minimal power while delivering precise moisture determination results. This efficiency allows it to be a cost-effective solution over time, as it reduces energy costs and supports sustainable practices in laboratory environments. With its low power demand, the GenMoist is both practical and economical, ideal for continuous or high-frequency testing without excessive energy use.
Click here to learn more about the product or here to receive a personalized quote.
The Moisture Determination Balance - GenMoist weighs 7 kg (approximately 15.4 pounds). This measurement refers to the net weight of the device itself, excluding packaging and additional accessories. At this weight, the GenMoist is manageable in standard laboratory or testing environments, where portability and ease of placement are often necessary.
Its 15 lbs / 7 kg weight supports stable operation on most lab benches while remaining light enough to be relocated if needed. This balance of stability and portability makes the GenMoist ideal for laboratories, industrial settings, and quality control stations that may require occasional repositioning. The device's manageable weight facilitates flexible setup options, enabling users to integrate it efficiently into their workflow.
Click here to learn more about the product or here to receive a personalized quote.
The dimensions of the Moisture Determination Balance - GenMoist measures 13.4 x 7.7 x 3.7 inches (340 x 194 x 95 mm). Because of its compact dimensions, it is ideal for laboratories and testing environments in which space is limited, allowing it to be placed comfortably on a workbench or within a testing station.
With its small footprint, the GenMoist is designed for easy integration into different setups, offering convenience without sacrificing performance. These dimensions support both stability and accessibility, enabling users to perform moisture determinations efficiently in confined or shared lab spaces. Its compact size allows the GenMoist can be positioned for convenient access, helping maintain a smooth and organized workflow.
Click here to learn more about the product or here to receive a personalized quote.
The Moisture Determination Balance - GenMoist uses an RS-232 data interface, a widely used serial communication port that allows the device to connect with computers and other data management systems. This interface enables users to transfer measurement data directly from the balance to external devices, facilitating efficient data logging, analysis, and record-keeping.
The RS-232 interface supports easy integration with laboratory information management systems (LIMS) or other software, which is particularly useful for users who need to track or analyze moisture determination results over time. By allowing easy data export, the RS-232 connection improves the balance’s functionality, allowing it to be used in laboratories and quality control environments in which accurate, retrievable data is essential.
Click here to learn more about the product or here to receive a personalized quote.
The Moisture Determination Balance - GenMoist is beneficial for professionals and industries that require precise moisture content analysis of solid samples. Laboratories, quality control departments, and research facilities in a number of sectors, such as environmental science, agriculture, food processing, pharmaceuticals, and soil mechanics, find this tool extremely useful.
In soil mechanics and environmental labs, for example, the GenMoist is a necessary tool for analyzing moisture levels in soil samples to assess soil properties for construction or agricultural applications. Food processing and the pharmaceutical industries rely on accurate moisture measurement to guarantee product quality, stability, and compliance with industry standards. Researchers and quality control technicians can benefit from GenMoist’s automation, high resolution, and data interface, allowing for more efficient testing, reliable results, and efficient data management.
Click here to learn more about the product or here to receive a personalized quote.
The new MULTISPEED tester is the ideal solution for Road testing laboratory. The 50 kN capacity and the fully variable test speed of 0.2 to 51 mm/min make it possible to perform not only the CBR and Marshall tests, but many other applications as for instance Indirect Tensile test, Quick Triaxial tests, Unconfined and Uniaxial soil testing and, in general, all test to be performed under displacement control. The machine can be equipped with analogical or digital load/displacement measurement systems as well as with the specific accessories, to suit either the field or central laboratory requirement.
Dynatriax systems are ideal for commercial and research laboratories for the following applications: Liquefaction potential, Strength degradation due to cyclic loading, Shear modulus and damping ratio, resilient modulus, Effects of blasting in mines and quarries, Effect of ocean waves on costal and off shore structures.
Automatic Triaxial Testing System for soil mechanics laboratory testing in compliance with the latest industry standards.
This test determines the rate and magnitude of consolidation of a soil specimen restrained laterally and subjected to a number of successive increments of vertical loads.
ACE - is the most advanced automatic computerized oedometer for testing soil consolidation that can measure the response of soil specimens.
The SHEARMATIC 300 automatic machine is ideal for testing geosyntetics and also soil and other materials that contain large particles of up to 20 mm largest dimension. Sample size up to 300 mm square can be tested, with inserts allowing the testing of smaller sample sizes. See accessories.
RESONANT COLUMN combines the features of both resonant column and torsional shear into a single unit including the current driven motor to apply torsional load to sample, a series of transducers with signal conditioning, a cell and back pressure electro-pneumatic control system and a data logger.
The microprocessor control system, therefore, allows the machine to work as an automatic stand-alone unit: the test measurements (force and displacements) a re directly displayed and stored in memory according to pre-set recording modes. The PC is only temporary required to download the test data via the RS 232 port once the test is completed. The data can be processed by the Direct and residual shear Geo-Analysis templates. See accessories.
This microprocessor based advanced model, is a stand-alone machine, driven by a high-resolution stepper motor with epicyclical reduction gear with reduced backlash. Incorporate a pneumatic closed loop system for the automatic application of the axial pressure by a high performance pressure regulator, with the main advantage of eliminating the manual loading of the dead weights. Excellent and high resistance techno-polymeric material has been adopted for the carriage of the shear box. It offers excellent resistance to corrosion, wear and tear and is resistant to all chemicals found in a soil specimen. The carriage is lightweight and easy to clean.
The laboratory vane apparatus is based on an original concept of the Transport and Road Research Laboratory of the United Kingdom. It offers versatility with a variety of vane sizes available. Typically it comes with the standard 12.7 mm square vane along with a set of four calibrated springs. Testing can be conducted either directly on the sample or within the sampling tube. For the latter, the NG-WF1738 Attachment for 38 and 100 mm diameter sampling tubes is recommended for optimal performance.